The following information is regarding storage heaters containing asbestos and a list of models both known to of been manufactured with asbestos as well as those free from asbestos. This information is everything we have available. If after reading this information you are still unsure then you must treat your heater as potentially containing asbestos. If you are looking to remove your heaters we recommend you seek a professional who can uninstall them and is equipped to safely deal with and dispose of asbestos.
___________________________________________________________________________________
DIMPLEX MODELS
Dimplex Storage Heaters Manufactured with Asbestos
Dimplex Limited, manufactured the following Storage Heaters incorporating asbestos based thermal insulating materials between 1964 and 1967:-
Models Containing Asbestos:
DSH150 DSH44 DSH34 DSH225 DSH45 DSH35 DSH300 DSH46 DSH38 DSH42 DSH48 DSH310 DSH43 DSH33 DSR44 DSR42 DSR43
These heaters had distinctive round corners, and the model number is stated on the rating label of the heater.
Dimplex Storage Heaters Manufactured without Asbestos
The following Dimplex Heaters DO NOT incorporate asbestos insulating materials with the approximate 1st year model was manufactured:
All Pre-1970:
HB 8/200, HB 8/260 & HB 8/330
HB 8/200, HB 8/260 & HB 8/330
DS 8/200, DS 8/260 & DS 8/330
HB 11/150, HB 11/225 & HB 11/300
HB 11/150, HB 11/225 & HB 11/300
DS 11/150, DS 11/225 & DS 11/300
1970 - D81, DA82, DA83
1970 - DFC85
1970 - DFB84
1972 - DA81, DA82, DA83
1972 - HC81, HC82 HC83
1980 - SC12, SC18, SC24
1980 - EC12, EC18, EC24
1983 - XT12, XT18, XT23
1983 - XTE12, XTE18, XTE24
1986 - CXT12, CXT18, CXT24
1986 - CXTE12, CXTE18, CXTE24
1990 - XLT6
1987 - XL12, XL18, XL24
1988 - XLE12, XLE18, XLE24
1988 - CXL12, CXL18, CXL24
1992 - XLS12, XLS18, XLS24
1992 - XL12N, XL18N & XL24N (N)
1991/2 - FCX18, FCX24
1993 - FCXA18, FCXA24
1994 - XL6N, XLS6N
1997 - FXL18 FXL24
2003 - DuoHeat (i) - DUO300i, DUO400i & DUO500i
2009 - DuoHeat (N) DUO300N, DUO400N & DUO500N
2012 - Quantum, QM050, QM070, QM100, QM125, QM150
2018 - XLE, XLE050, XLE070, XLE100, XLE125, XLE150
2020 - Quantum RF, QM050RF, QM070RF, QM100RF, QM125RF, QM150RF
If your model cannot be found in the above list, further information may be obtainable from:
https://www.armco.org.uk/asbestos-survey-news/storage-heaters-that-contain-asbestos/
or
___________________________________________________________________________________
Creda Models
See this seperate article for Creda branded products.
___________________________________________________________________________________
UNIDARE MODELS
Unidare Heaters Manufactured with Asbestos
Unidare products containing asbestos include:
DCFA
CUE
DCO
270
HCS - Models manufactured prior to 20th September 1973
The change over to serial numbers which are free from asbestos:
HCS 16 009259
HCS 21 022634
HCS 27 030215
Unidare Heaters Manufactured without Asbestos
SA Range
SF Range
WF Range
WM Range
WMX Range
WMS Range
WMC Range
WMCS Range
MS Range
___________________________________________________________________________________
ELECTRICAIRE MODELS
Electricaire Units; The last 2 digits of the serial number indicate the year of manufacture. All units made after 1974 are asbestos free. Electricaire Units are sometimes referred to as Comfortaire heaters but NOT to be confused with the Comfortair heater (spelling). Comfortair was formerly the Redring Sunstore heater.
377 "E" type (distinguished by being a grey coloured unit)
"S" Type heater (distinguished by being a chimney breast shape)
"SF 6" Type (chimney breast)
"SB Type" (chimney breast)
Important Notes:
The above storage / storage fan heaters and E Type Heaters contained medium density semi-rigid insulation slabs of "Caposil HTI", situated more normally as base insulation of the core box containing the storage bricks. This material contained 10/15% brown asbestos (Ammosite), the balance being harmless calcium silicate.
Some of the heaters also contained a piece of Asbestolux (asbestos cement board). This contained 16/25% brown asbestos and a small un-quantified amount of white asbestos (Chrysolite).
The "S", "SF6", and "SB" Electricaire heaters contain a small sheet of "Viceroy" (Asbestos paper and aluminium foil corrugations 1" thick) in the warm air unit where the fans would be situated), either side of the fan unit.
___________________________________________________________________________________
Further Advice
The above information if everything we have available. If you are unsure or have any reason to suspect your heater might contain asbestos ensure you seek a professional who can uninstall your heaters and is equipped to safely deal with and dispose of asbestos.