Can I install a panel heater fitted to a plug?

Modified on Mon, 19 Feb at 11:49 AM

No, this appliance must be hard wired to fixed wiring of the premises in accordance with manufactures instructions and a means of disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. 


The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm. The use of 3 pin 13A plug tops is not permitted.


Applicable to models: 

PLX050E PLX075E PLX100E PLX125E PLX150E GFP050BE GFP075BE GFP100BE GFP150BE GFP200BE

GFP050WE GFP075WE GFP100WE GFP150WE GFP200WE MFP050E MFP075E MFP100E MFP150E MFP200E

LPP050E LPP075E LPP100E LPP150E QRAD050RF QRAD075RF QRAD100RF QRAD150RF QRAD200RF

QRAD050E QRAD075E QRAD100E QRAD150E QRAD200E BPH100M BH100G CEP500E CEP750E CEP1000E CEP1500E CEP2000E CEP050E CEP075E CEP100E CEP150E CEP200E LST050E LST075E LST100E LST150E