Quantum Series G showing error code 001. What does this mean?

Modified on Tue, 1 Aug, 2023 at 11:48 AM

If the error occurs within 2 mins of the heater being powered on, it means the core temperature sensor is misreading.

Take Part 10855G & QMKIT2 as it could be the Core Temperature sensor or the Charge Controller at fault.

DO NOT SEND JUST THE CHARGE CONTROLLER NEEDS TO BE COMPLETE QMKIT2 due to software compatibility.

If the error occurs after 2 mins or it randomly happens after some time, this suggests a software issue. Engineer to attend with part QMKIT2.


In guarantee, please submit a ticket.

If out of warranty, contact nearest service agent to attend see additional help link for list of service agents below.

Applicable to: QM050 QM070 QM100 QM125 QM150


Require additional help? Please follow link below

https://glendimplexservice.freshdesk.com/a/solutions/articles/79000136321





Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article